Jovane pozdrav!!
- izaberi rezim rada u mm...Configure- setup units-
mm- ok
- za pokretanje masine (motora ) rucno .... Configure- Set axis hot keys- ( izaberi na strelice i page up page down)-ok
-configure-portts and pins-
port 1 (enable),
x asix - enabled,
y asix - enabled,
z asix - enabled ,
karnel speed 35000
- configure - port and pins - imput emulation..... sve ostavi odcekirano
- configure- port and pins- input signals -
limit x ++, limit x --,
limit y ++, limit y --,
limit z ++, limit z --,
emergency stop i
OEM trigger 2 sve chekiraj.
- configure - port and pins - Input pins ...
limit x plus 1-15 ,
limit x minus,1-15,
limit y plus 1-15 ,
limit y minus,1-15,
limit z plus 1-15 ,
limit z minus,1-15,
ostalo staviti 1-0,
emergenci stop 1-13,
OEM trigger 1-12,
OEM trigger 2 1-12.
ostalo staviti 1-10
sve chekirati , u slucaju problema odchekirati sve limite.
- configure - port and pins-output signals....
enable line 1,chekirati
output 1 ... chekirti
-configure - pins and ports - output pins..
enable line 1 ...1-8 ,
x axis step 1-2,
x axis direction ..1-3,
y axis step 1-4,
y axis direction ..1-5,
z axis step 1-6,
z axis direction ..1-7,
paljenje frezera ..1-9,
charge pump safety 1-16,
charge pump 2 .. 2-17,
trebalo bi da radi onda.
|